D180 AutoGen

Up to 10 kW connected diesel DC generator for 48V battery backup charging.

D180 AutoGen is a turnkey connected DC generator package built around the Kohler KD425-2 diesel engine, variable-RPM generator, permanent magnet alternator, adjustable charging current up to 180 A, and adjustable charging voltage up to 57.6 V. AutoGen control adds automatic starting, app and dashboard access, local access, API support, and dealer fleet tools.

Up to 10 kW Kohler KD425-2 Net weight 82 kg Variable-RPM generator Permanent magnet alternator Adjustable up to 180 A / 57.6 V WiFi or LTE GPS with LTE Dealer fleet support
D180 AutoGen 48V DC diesel generator

High-output charging with connected AutoGen control.

D180 combines adjustable 48V charging with automatic generator control, connected monitoring, and support tools for larger battery banks and remote installations.

Adjustable high-output charging

D180 provides up to 10 kW, with charging current adjustable up to 180 A and charging voltage adjustable up to 57.6 V.

Automatic charging control

AutoGen manages configured start conditions, engine starting, run confirmation, charging state, stopping, runtime history, and supported alerts.

Remote and local visibility

Use the app and web dashboard through WiFi or LTE, with BLE setup and WiFi Local AP access available nearby.

Dealer and integration support

API access, firmware workflows, fleet tools, and diagnostic events support authorized dealers and system integrations.

D180 generator and control hardware.

Product views show the Kohler diesel engine, permanent magnet alternator, mounted AutoGen controller, and service-facing connections.

D180 AutoGen full side generator view

Complete generator package

D180 with the Kohler KD425-2 engine, permanent magnet alternator, AutoGen controller, and mounting hardware.

D180 AutoGen controller mounted detail

Mounted AutoGen controller

The AutoGen controller mounted on D180 with its cable and connector side visible.

D180 AutoGen front connector vertical detail

Service connections

Connector and service components at the engine end of the generator.

Kohler engine and permanent magnet alternator.

Closer views of the engine, alternator, and assembled D180 generator package.

D180 AutoGen engine-side detail

Kohler KD425-2 engine

Engine and service components used in the D180 diesel generator package.

D180 AutoGen alternator front detail

Permanent magnet alternator

The aluminum alternator housing supports heat dissipation around the permanent magnet alternator.

D180 AutoGen product hero image

Complete D180 generator

Assembled D180 AutoGen generator with the engine, alternator, and controller in one compact package.

Connected monitoring, control, and service tools.

D180 connects the generator to the AutoGen app and web dashboard for live operating data, schedules, settings, device management, firmware support, API access, and dealer assistance.

AutoGen telemetry dashboard

Telemetry dashboard

Live generator state, battery voltage, charging current, runtime, temperatures, and operating data.

AutoGen app device list

App device access

Owners, installers, and authorized support teams can find and open the correct AutoGen device.

AutoGen weekly schedule settings

Schedules and settings

Adjust charging profiles, scheduled runtimes, start and stop behavior, temperature limits, and supported options.

AutoGen dealer fleet console

Dealer fleet support

With customer permission, authorized dealers can review device state, service information, and firmware remotely.

AutoGen admin and dealer diagnostic events dashboard

Diagnostic events

Event history records starts, stops, run confirmation, faults, resets, communication state, and firmware actions.

Is D180 the right size for the installation?

Choose D180 when the required charging output, battery-bank size, daily energy demand, or runtime makes it the best fit in the AutoGen range.

Best fit

Larger off-grid systems, technical sites, remote infrastructure, and backup installations that need charging output up to 10 kW and 180 A.

Use D100 instead

Choose D100 when the site still needs diesel 48V DC charging and connected support, but the 10 kW D180 package is more capacity than the installation requires.

Use V100 instead

Choose V100 when the installation is smaller, lighter, or better suited to the Honda GX390 petrol generator package.

Measured performance, manual, and API documentation

Open the D180 performance report, setup manual, and API documentation for measured test data, configuration, and integration details.

D180 AutoGen Kohler KD425-2 side profile

D180 product questions.

Key points about charging output, connectivity, direct DC charging, and choosing D180 over D100.

When should I choose D180 instead of D100?

Choose D180 when the installation needs charging output up to 10 kW or current up to 180 A. D100 provides up to 5.6 kW and 100 A in a smaller single-cylinder diesel package.

Does D180 include connected monitoring?

Yes. Depending on configuration, D180 can use WiFi or LTE for cloud access, with app and dashboard visibility, BLE setup, WiFi Local AP, API support, and dealer tools. GPS is available with the LTE version.

Does D180 charge a 48V battery bank directly?

Yes. The permanent magnet alternator provides adjustable DC charging output up to 180 A and 57.6 V, without using a conventional AC-first generator and external battery-charger path.

Who is D180 for?

D180 suits larger off-grid battery banks, hybrid backup systems, telecom and technical sites, remote infrastructure, and installations that need up to 10 kW of connected diesel charging.

Customer feedback

Read Google reviews and feedback imported from earlier AutoGen customer projects.

Read feedback

Need help choosing the right AutoGen DC generator?

Send the battery-bank size, required charging current, site connectivity, and deployment type, and we can point you to the right AutoGen generator.

Contact us