AutoGen V100 D100 D180 48V DC Generators

AutoGen DC Generator Lineup

Connected 48V DC generators for off-grid battery charging.

Choose from AutoGen DC generator packages when you want automated 48V battery charging, permanent magnet alternator hardware, app access, cloud monitoring, local setup tools, documentation, and dealer support supplied as one connected system.

48V DC charging WiFi or LTE cloud BLE terminal WiFi Local AP LTE-only GPS option Dealer support

Complete DC generator backup solution for any 48V battery bank.

Choose from our turn-key AutoGen DC Generator packages when you want automated or hybrid backup charging, apps, cloud connection, local access, API support, documentation, and a dealer support path supplied as one connected 48V DC system.

D180 AutoGen Kohler engine-side detail

D180 AutoGen

Higher-output 10 kW class connected diesel generator for demanding 48V DC battery charging, remote infrastructure, backup power, and fleet-managed sites where runtime visibility and support data matter.

10 kW classKohler KD425-2Variable rpm generatorAdjustable current up to 180 AAdjustable voltage up to 57.6 VPermanent magnet alternator
V100 AutoGen 48V DC generator

V100 AutoGen

Compact 48V DC generator with Honda GX390 for off-grid battery charging, cabins, mobile power, and smaller remote sites.

5.6 kW classHonda GX390Variable rpm generatorAdjustable current outputAdjustable voltage up to 57.6 VPermanent magnet alternator
D100 AutoGen diesel 48V DC generator

D100 AutoGen

Diesel 48V DC generator for larger off-grid battery banks, backup power, technical sites, and dealer-supported installations.

5.6 kW classKohler KD15-440Variable rpm generatorAdjustable current up to 100 AAdjustable voltage up to 57.6 VPermanent magnet alternator

Direct charging, connected visibility, and support-ready data.

AutoGen DC generators are designed around compact packaging, reliable charging, permanent magnet alternator hardware, connected monitoring, practical service access, and technical references that help customers choose confidently.

Direct 48V DC charging

Designed for battery-bank charging instead of a generic AC-first generator workflow.

Permanent magnet alternators

Compact alternator hardware selected for reliable DC charging packages.

Connected dashboard

Supported units show generator state, battery voltage, runtime, temperatures, firmware, schedules, alerts, and service values.

Dealer support path

With the correct customer scope, dealers can review state, firmware, service needs, GPS location where fitted, and support actions.

From battery demand to confirmed charging.

The platform is built to show what is happening clearly: start conditions, run confirmation, charging state, runtime, schedules, service values, and alerts.

Start condition

The controller can react to configured battery-bank conditions, schedules, supported signals, or approved remote commands.

Generator starts

Start control, run confirmation, retry logic, and protective states are handled by the AutoGen control system.

Charging is visible

Supported systems report voltage, current where fitted, temperatures, runtime, firmware, and service values.

Owners can see it

The app and dashboard show live state, controls, history, schedules, alerts, and supported settings.

Dealers can support it

Authorized dealers can use fleet tools, firmware workflows, and device support pages remotely.

Start with the battery bank and required charging current.

The best choice depends on battery-system size, fuel preference, charging target, connectivity, local access needs, and whether dealer fleet support or LTE GPS is required.

ProductBest fitCharging targetConnected platform
V100 AutoGenCompact petrol charging for lighter off-grid and mobile power sitesAdjustable voltage and current output for 5.6 kW class 48V DC charging with Honda GX390WiFi or LTE cloud, BLE terminal, WiFi Local AP, LTE-only GPS option
D100 AutoGenCompact diesel charging for larger battery banks and technical sitesAdjustable current up to 100 A and adjustable voltage up to 57.6 VCloud dashboard, app access, local access, dealer support, measured report
D180 AutoGenHigher-output diesel charging for demanding backup and remote infrastructureAdjustable current up to 180 A and adjustable voltage up to 57.6 VCloud dashboard, app access, local access, dealer support, measured report

Reports, manuals, API links, and product details belong with the decision.

Individual product pages carry the deeper photos, specifications, measured reports, manuals, API references, configuration options, and support references needed before ordering.

V100

Compact petrol 48V DC package with Honda GX390, variable rpm generator, adjustable voltage/current output, and connected AutoGen control.

Open V100

D100

Compact diesel 48V DC package with Kohler KD15-440, adjustable current up to 100 A, and measured report support.

Open D100

D180

Higher-output diesel 48V DC package with Kohler KD425-2, adjustable current up to 180 A, and measured report support.

Open D180

Manual and API references

Generator manuals, firmware notes, API documents, and dealer workflows support setup, integration, and service.

Open docs hub

Questions before choosing a DC generator.

Start with the battery bank, target charge current, fuel choice, site connectivity, local access needs, and whether dealer fleet support is required.

Is this direct 48V DC charging?

Yes. V100, D100, and D180 are AutoGen 48V DC battery-charging generator packages with variable rpm generator, adjustable voltage and current output, permanent magnet alternator hardware, and AutoGen control.

Which model should I start with?

Choose V100 for compact petrol charging, D100 for compact diesel charging up to 100 A, and D180 for higher-output diesel charging up to 180 A.

Can dealers support deployed units?

Yes. AutoGen supports dealer fleet tools, scoped customer access, firmware workflows, API tokens, and single-device support workflows.

Is GPS available on every version?

No. GPS belongs with LTE configurations. WiFi-only configurations should not be presented with GPS as a selectable option.

Customer feedback

Read Google reviews and feedback imported from earlier AutoGen customer projects.

Read feedback

Send the site requirements and we will match the DC generator.

Include battery-bank details, target charge current, fuel preference, daily energy requirement, connectivity, local access needs, and whether LTE GPS or dealer fleet support is required.

Contact us